The rack-and-pinion follower is always combined with a rack-and-pinion actuator of the EA-SZ type with the same stroke. By combining a rack-and-pinion runner and a rack-and-pinion actuator, cost-effective solutions are created to provide large / wide windows with 2 closing points without the need of..
The 24V DC folding arm actuator PA-KL²-DF is a further development of the successful folding arm actuator PA-KL². This "DF" version has been specially developed for both inward and outward opening side-hung windows, but can certainly also be used on top- and bottom hung windows. Ideally suited for w..
The optical smoke detector RM-3000 works on the scattered light principle. A light transmitter and receiver are mounted in the plastic housing. The light beam does not hit the receiver in normal condition. As soon as smoke particles are detected in the air between the transmitter and receiver, the l..
The thermal detector TH-4860 contains two thermal sensors that can detect fire at an early stage and thus quickly give an alarm message to an SHEV system and/or a fire alarm panel.A thermal detector can alternatively be used in rooms where a smoke detector is less suitable and can therefore give a f..
Siren S24 is an acoustic, multi-tone alarm indicator that is used during SHE activation.In the event of emergencies, you are quickly warned of the danger and the evacuation of people inside the building can start on time. This makes it very useful in buildings where many people gather, such as..
Heavy lift 24 Volt DC linear actuator with a stroke of 1000mm. and a push / pull force of max.1800N. with Tandem function.
Widely applicable on heavy windows, skylights and roof windows for daily ventilation or SHEV systems. (acc. EN 12101/2).The tandem function allows to connect up to 4 actuat..
The BI-24 is an optical alarm indicator that is used during SHE activation. In case of emergencies, you are quickly warned of the danger and the evacuation of people inside the building can start on time. This makes it very useful in buildings where many people gather, such as shopping centers, scho..
The rain detector RD is designed for
connection to SHE and ventilation control panels of SIMON PROtec. The detector prevents that automated windows stay open or will be opened in case of excessive rain. A heated sensor surface avoids
false triggering by snow, ice or dew. The period of time to re..
The wind-rain detector WRD is designed for
connection to SHE and Ventilation control panels of SIMON PROtec. The wind detector (anemometer) measures the wind that blows past the turbine and compares the measured values with the set values. When the windforce exceeds a preset value, the connected w..
The AM-600 safety control unit shuts down the actuators if a safety
contact triggers or there is a line break at that contact. It comes to
switching off the electromechanical actuator in the "CLOSE" direction.
It must first be given a control of the electrical control device in the
OPEN dire..
Thermostat TH is used as an internal temperature-dependent
automatic release for ventilation purposes in SHE and ventilation
systems. This thermostat is a two-position controller and switches with a
change-over contact at the set threshold. The continuous signal is
returned and
evaluated b..